Vision
Sign in
Atlas Metrology/XPS

XPS analysis, from vendor file to chemical state

Atlas covers the full XPS workflow: import from every major vendor, inspection of acquisition conditions and counting statistics, energy referencing with a recorded basis and uncertainty, tiered survey identification, constrained core-level fitting with a uniqueness test, and comparison with literature values and multiplet simulations.

See a full walkthrough
Loading figure…
Constrained Mo 3d fit of an aged MoS₂ film. The MoO₃ doublet is pinned to ±0.02 eV and a perturbation test moves its area by only 4.4 %, so the 51 % oxide area fraction is reported as determined. The same test on the fresh film reported the oxide as unsupported. Data: Píš, Bondino, Sojková, Zenodo, CC-BY-4.0.
How Atlas produced this result

What Atlas does with XPS data

Every analysis runs as a documented Block with recorded parameters, so the same result can be reproduced, reviewed, and compared across samples.

  • One workflow for every vendor

    VAMAS, PHI MultiPak, SPECS Prodigy, Scienta Omicron, and CasaXPS text exports all land on the same metadata schema, so a lab with a mixed instrument fleet runs one workflow.

  • Inspection before interpretation

    Atlas reports acquisition conditions and counting statistics first, and refuses to compute statistics the measured ordinate cannot support.

  • Energy referencing with a receipt

    Reference to Au, Ag, or Cu with ISO 15472 values, to a fitted Fermi edge, or to adventitious carbon, with the basis and uncertainty of every shift written into the dataset.

  • Constrained fits, checked for uniqueness

    Templates link spin–orbit doublets and require a reason for every component. A perturbation test then shows whether the data can actually distinguish them.

  • Tiered element identification

    Survey lines are identified in confidence tiers rather than as a flat list, and a suggested assignment is never promoted to accepted automatically.

  • Literature and multiplet models

    Compare a measured binding energy with a corpus of reported values and their referencing context, or overlay an atomic-multiplet or charge-transfer simulation on a transition-metal region.

Atlas compared with legacy XPS software

Most labs already own capable XPS software. This is where Atlas adds to it, and where your existing tools are still the better choice.

X-ray photoelectron spectroscopy: Matter42 Atlas compared with instrument vendor software and desktop analysis tools
CapabilityMatter42 AtlasCloud or private deploymentInstrument vendor softwaree.g. Avantage, MultiPak, SpecsLab ProdigyDesktop analysis toolse.g. CasaXPS, Origin
Importing data from several vendors

Supported. VAMAS plus PHI, SPECS, Scienta, and CasaXPS exports, in one schema.

Partly supported. Own formats; VAMAS export usually available.

Supported. Broad format support.

Constrained fitting with linked doublets

Supported. Template-driven, with a stated reason for every component.

Supported. Standard.

Supported. Standard and highly configurable.

Checking whether a fit is unique

Supported. Perturbation test runs by default; unsupported components flagged.

Partly supported. Fit statistics; uniqueness checks usually manual.

Partly supported. Error estimates available in some tools, run on request.

Energy referencing recorded with basis and uncertainty

Supported. Every shift stored with its method and uncertainty.

Partly supported. Calibration applied; basis often kept as a note.

Partly supported. Calibration shift stored with the file.

Counting-statistics checks before fitting

Supported. Reported for every region.

Partly supported. Left to the analyst.

Partly supported. Left to the analyst.

Atomic-percent quantification

Not supported. Not yet. On the roadmap.

Supported. With built-in sensitivity-factor libraries.

Supported. With configurable sensitivity factors.

Comparison with published binding energies

Supported. Searchable corpus with referencing context and citations.

Partly supported. Built-in reference tables.

Partly supported. Element libraries; literature by hand.

Multiplet and charge-transfer simulation

Supported. Atomic-multiplet and charge-transfer models overlaid on data.

Not supported. Separate specialist codes.

Not supported. Separate specialist codes.

Results tied to samples and process history

Supported. Referenced positions, widths, and area fractions are stored as structured outputs linked to the file, parameters, sample, and process run.

Partly supported. Project files on the workstation; sample context kept separately.

Partly supported. Saved project files; sample context kept by hand.

Instrument control and acquisition

Not supported. Not an acquisition tool. Keep your instrument software for this.

Supported. Core purpose.

Not supported. Not offered.

  • Supported
  • Partly supported
  • Not supported

Reflects typical, publicly documented workflows in each category as of September 2026. Capabilities vary by product, version, and add-on module. Product names are trademarks of their respective owners.

Where Atlas stops

A result is only useful if you know its limits. These are the current boundaries, stated in the product the same way.

  • Atomic-percent quantification is not shipped yet. It needs a named sensitivity-factor set, a transmission correction, and compatible pass energies, and it is next on the roadmap. Use your current software for it today.
  • Atlas does not name a chemical state from a survey spectrum or accept a fit whose components the data cannot distinguish.
  • Area fractions are reported within a core-level region. They are not oxide thicknesses or atomic percentages.
  • The generic peak fitter refuses XPS data and points to the constrained XPS workflow instead.

Files Atlas reads

  • VAMAS (.vms, .npl)
  • PHI MultiPak (.spe, .pro depth profiles)
  • SPECS SpecsLab Prodigy (.xy)
  • Scienta Omicron (.txt)
  • CasaXPS text exports

Analysis Blocks

  • Inspect XPS spectrum
  • Identify XPS elements
  • Reference XPS energy
  • Fit XPS core level
  • Estimate XPS layer thickness
  • Look up XPS literature

Worked examples

  • Technical walkthrough · 13 min read

    From envelope to evidence: what Atlas can do with XPS

    A published MoS₂ VAMAS corpus, fresh and two years later: vendor-agnostic import, survey identification, energy referencing with recorded provenance, and a constrained Mo 3d / S 2p fit that says when it cannot tell oxide from noise — and when it can.

Questions

Is Atlas a CasaXPS alternative?
For importing, referencing, constrained fitting, and checking whether a fit is unique, yes. For atomic-percent quantification, keep CasaXPS or your vendor software for now; that capability is on the Atlas roadmap. Atlas reads CasaXPS text exports and records any CasaXPS processing embedded in a VAMAS file without silently applying it.
Can Atlas read depth profiles?
Yes. A PHI MultiPak .pro depth profile becomes one dataset per sputter cycle, with the sputter ion and energy recorded, so each cycle can be referenced and fitted like any other region.
How does Atlas handle charge referencing?
As an explicit, reviewable step. You choose a deposited marker, a Fermi edge, an internal line, or adventitious carbon, and the method, offset, and uncertainty are recorded on every derived dataset. Kinetic-energy exports are converted using the recorded source energy and work function.

Other techniques

  • Raman spectroscopy
  • Photoluminescence spectroscopy
  • X-ray diffraction
  • Atomic force microscopy

Bring your XPS data

Send us a file from your own instrument. We’ll run it through Atlas and walk you through every number and caveat it reports.

All techniques
Matter42

A world model for your materials: know what you made and decide what to make next, with the evidence attached.

Platform

  • Atlas Metrology
  • Atlas Physics AI
  • Literature

Software

  • Raman analysis
  • PL analysis
  • XPS analysis
  • XRD analysis
  • AFM analysis

Company

  • Vision
  • Team
  • Careers
  • Blog

Resources

  • Documentation
  • Python SDK
  • Security and deployment
  • FAQ

Legal

  • Privacy Policy
  • Terms and Conditions

Social

  • LinkedIn

Copyright © 2026 Matter42. All rights reserved.

Matter42
  • Vision
Sign in

Matter42 Atlas

  • Atlas Metrology
  • Atlas Physics AI

Resources

  • Security
  • FAQ
  • Documentation
  • Python SDK

Company

  • Team
  • Careers
  • Blog
Vision
Sign in
Atlas Metrology/XPS

XPS analysis, from vendor file to chemical state

Atlas covers the full XPS workflow: import from every major vendor, inspection of acquisition conditions and counting statistics, energy referencing with a recorded basis and uncertainty, tiered survey identification, constrained core-level fitting with a uniqueness test, and comparison with literature values and multiplet simulations.

See a full walkthrough
Loading figure…
Constrained Mo 3d fit of an aged MoS₂ film. The MoO₃ doublet is pinned to ±0.02 eV and a perturbation test moves its area by only 4.4 %, so the 51 % oxide area fraction is reported as determined. The same test on the fresh film reported the oxide as unsupported. Data: Píš, Bondino, Sojková, Zenodo, CC-BY-4.0.
How Atlas produced this result

What Atlas does with XPS data

Every analysis runs as a documented Block with recorded parameters, so the same result can be reproduced, reviewed, and compared across samples.

  • One workflow for every vendor

    VAMAS, PHI MultiPak, SPECS Prodigy, Scienta Omicron, and CasaXPS text exports all land on the same metadata schema, so a lab with a mixed instrument fleet runs one workflow.

  • Inspection before interpretation

    Atlas reports acquisition conditions and counting statistics first, and refuses to compute statistics the measured ordinate cannot support.

  • Energy referencing with a receipt

    Reference to Au, Ag, or Cu with ISO 15472 values, to a fitted Fermi edge, or to adventitious carbon, with the basis and uncertainty of every shift written into the dataset.

  • Constrained fits, checked for uniqueness

    Templates link spin–orbit doublets and require a reason for every component. A perturbation test then shows whether the data can actually distinguish them.

  • Tiered element identification

    Survey lines are identified in confidence tiers rather than as a flat list, and a suggested assignment is never promoted to accepted automatically.

  • Literature and multiplet models

    Compare a measured binding energy with a corpus of reported values and their referencing context, or overlay an atomic-multiplet or charge-transfer simulation on a transition-metal region.

Atlas compared with legacy XPS software

Most labs already own capable XPS software. This is where Atlas adds to it, and where your existing tools are still the better choice.

X-ray photoelectron spectroscopy: Matter42 Atlas compared with instrument vendor software and desktop analysis tools
CapabilityMatter42 AtlasCloud or private deploymentInstrument vendor softwaree.g. Avantage, MultiPak, SpecsLab ProdigyDesktop analysis toolse.g. CasaXPS, Origin
Importing data from several vendors

Supported. VAMAS plus PHI, SPECS, Scienta, and CasaXPS exports, in one schema.

Partly supported. Own formats; VAMAS export usually available.

Supported. Broad format support.

Constrained fitting with linked doublets

Supported. Template-driven, with a stated reason for every component.

Supported. Standard.

Supported. Standard and highly configurable.

Checking whether a fit is unique

Supported. Perturbation test runs by default; unsupported components flagged.

Partly supported. Fit statistics; uniqueness checks usually manual.

Partly supported. Error estimates available in some tools, run on request.

Energy referencing recorded with basis and uncertainty

Supported. Every shift stored with its method and uncertainty.

Partly supported. Calibration applied; basis often kept as a note.

Partly supported. Calibration shift stored with the file.

Counting-statistics checks before fitting

Supported. Reported for every region.

Partly supported. Left to the analyst.

Partly supported. Left to the analyst.

Atomic-percent quantification

Not supported. Not yet. On the roadmap.

Supported. With built-in sensitivity-factor libraries.

Supported. With configurable sensitivity factors.

Comparison with published binding energies

Supported. Searchable corpus with referencing context and citations.

Partly supported. Built-in reference tables.

Partly supported. Element libraries; literature by hand.

Multiplet and charge-transfer simulation

Supported. Atomic-multiplet and charge-transfer models overlaid on data.

Not supported. Separate specialist codes.

Not supported. Separate specialist codes.

Results tied to samples and process history

Supported. Referenced positions, widths, and area fractions are stored as structured outputs linked to the file, parameters, sample, and process run.

Partly supported. Project files on the workstation; sample context kept separately.

Partly supported. Saved project files; sample context kept by hand.

Instrument control and acquisition

Not supported. Not an acquisition tool. Keep your instrument software for this.

Supported. Core purpose.

Not supported. Not offered.

  • Supported
  • Partly supported
  • Not supported

Reflects typical, publicly documented workflows in each category as of September 2026. Capabilities vary by product, version, and add-on module. Product names are trademarks of their respective owners.

Where Atlas stops

A result is only useful if you know its limits. These are the current boundaries, stated in the product the same way.

  • Atomic-percent quantification is not shipped yet. It needs a named sensitivity-factor set, a transmission correction, and compatible pass energies, and it is next on the roadmap. Use your current software for it today.
  • Atlas does not name a chemical state from a survey spectrum or accept a fit whose components the data cannot distinguish.
  • Area fractions are reported within a core-level region. They are not oxide thicknesses or atomic percentages.
  • The generic peak fitter refuses XPS data and points to the constrained XPS workflow instead.

Files Atlas reads

  • VAMAS (.vms, .npl)
  • PHI MultiPak (.spe, .pro depth profiles)
  • SPECS SpecsLab Prodigy (.xy)
  • Scienta Omicron (.txt)
  • CasaXPS text exports

Analysis Blocks

  • Inspect XPS spectrum
  • Identify XPS elements
  • Reference XPS energy
  • Fit XPS core level
  • Estimate XPS layer thickness
  • Look up XPS literature

Worked examples

  • Technical walkthrough · 13 min read

    From envelope to evidence: what Atlas can do with XPS

    A published MoS₂ VAMAS corpus, fresh and two years later: vendor-agnostic import, survey identification, energy referencing with recorded provenance, and a constrained Mo 3d / S 2p fit that says when it cannot tell oxide from noise — and when it can.

Questions

Is Atlas a CasaXPS alternative?
For importing, referencing, constrained fitting, and checking whether a fit is unique, yes. For atomic-percent quantification, keep CasaXPS or your vendor software for now; that capability is on the Atlas roadmap. Atlas reads CasaXPS text exports and records any CasaXPS processing embedded in a VAMAS file without silently applying it.
Can Atlas read depth profiles?
Yes. A PHI MultiPak .pro depth profile becomes one dataset per sputter cycle, with the sputter ion and energy recorded, so each cycle can be referenced and fitted like any other region.
How does Atlas handle charge referencing?
As an explicit, reviewable step. You choose a deposited marker, a Fermi edge, an internal line, or adventitious carbon, and the method, offset, and uncertainty are recorded on every derived dataset. Kinetic-energy exports are converted using the recorded source energy and work function.

Other techniques

  • Raman spectroscopy
  • Photoluminescence spectroscopy
  • X-ray diffraction
  • Atomic force microscopy

Bring your XPS data

Send us a file from your own instrument. We’ll run it through Atlas and walk you through every number and caveat it reports.

All techniques
Matter42

A world model for your materials: know what you made and decide what to make next, with the evidence attached.

Platform

  • Atlas Metrology
  • Atlas Physics AI
  • Literature

Software

  • Raman analysis
  • PL analysis
  • XPS analysis
  • XRD analysis
  • AFM analysis

Company

  • Vision
  • Team
  • Careers
  • Blog

Resources

  • Documentation
  • Python SDK
  • Security and deployment
  • FAQ

Legal

  • Privacy Policy
  • Terms and Conditions

Social

  • LinkedIn

Copyright © 2026 Matter42. All rights reserved.

Matter42
  • Vision
Sign in

Matter42 Atlas

  • Atlas Metrology
  • Atlas Physics AI

Resources

  • Security
  • FAQ
  • Documentation
  • Python SDK

Company

  • Team
  • Careers
  • Blog
Vision
Sign in
Atlas Metrology/XPS

XPS analysis, from vendor file to chemical state

Atlas covers the full XPS workflow: import from every major vendor, inspection of acquisition conditions and counting statistics, energy referencing with a recorded basis and uncertainty, tiered survey identification, constrained core-level fitting with a uniqueness test, and comparison with literature values and multiplet simulations.

See a full walkthrough
Loading figure…
Constrained Mo 3d fit of an aged MoS₂ film. The MoO₃ doublet is pinned to ±0.02 eV and a perturbation test moves its area by only 4.4 %, so the 51 % oxide area fraction is reported as determined. The same test on the fresh film reported the oxide as unsupported. Data: Píš, Bondino, Sojková, Zenodo, CC-BY-4.0.
How Atlas produced this result

What Atlas does with XPS data

Every analysis runs as a documented Block with recorded parameters, so the same result can be reproduced, reviewed, and compared across samples.

  • One workflow for every vendor

    VAMAS, PHI MultiPak, SPECS Prodigy, Scienta Omicron, and CasaXPS text exports all land on the same metadata schema, so a lab with a mixed instrument fleet runs one workflow.

  • Inspection before interpretation

    Atlas reports acquisition conditions and counting statistics first, and refuses to compute statistics the measured ordinate cannot support.

  • Energy referencing with a receipt

    Reference to Au, Ag, or Cu with ISO 15472 values, to a fitted Fermi edge, or to adventitious carbon, with the basis and uncertainty of every shift written into the dataset.

  • Constrained fits, checked for uniqueness

    Templates link spin–orbit doublets and require a reason for every component. A perturbation test then shows whether the data can actually distinguish them.

  • Tiered element identification

    Survey lines are identified in confidence tiers rather than as a flat list, and a suggested assignment is never promoted to accepted automatically.

  • Literature and multiplet models

    Compare a measured binding energy with a corpus of reported values and their referencing context, or overlay an atomic-multiplet or charge-transfer simulation on a transition-metal region.

Atlas compared with legacy XPS software

Most labs already own capable XPS software. This is where Atlas adds to it, and where your existing tools are still the better choice.

X-ray photoelectron spectroscopy: Matter42 Atlas compared with instrument vendor software and desktop analysis tools
CapabilityMatter42 AtlasCloud or private deploymentInstrument vendor softwaree.g. Avantage, MultiPak, SpecsLab ProdigyDesktop analysis toolse.g. CasaXPS, Origin
Importing data from several vendors

Supported. VAMAS plus PHI, SPECS, Scienta, and CasaXPS exports, in one schema.

Partly supported. Own formats; VAMAS export usually available.

Supported. Broad format support.

Constrained fitting with linked doublets

Supported. Template-driven, with a stated reason for every component.

Supported. Standard.

Supported. Standard and highly configurable.

Checking whether a fit is unique

Supported. Perturbation test runs by default; unsupported components flagged.

Partly supported. Fit statistics; uniqueness checks usually manual.

Partly supported. Error estimates available in some tools, run on request.

Energy referencing recorded with basis and uncertainty

Supported. Every shift stored with its method and uncertainty.

Partly supported. Calibration applied; basis often kept as a note.

Partly supported. Calibration shift stored with the file.

Counting-statistics checks before fitting

Supported. Reported for every region.

Partly supported. Left to the analyst.

Partly supported. Left to the analyst.

Atomic-percent quantification

Not supported. Not yet. On the roadmap.

Supported. With built-in sensitivity-factor libraries.

Supported. With configurable sensitivity factors.

Comparison with published binding energies

Supported. Searchable corpus with referencing context and citations.

Partly supported. Built-in reference tables.

Partly supported. Element libraries; literature by hand.

Multiplet and charge-transfer simulation

Supported. Atomic-multiplet and charge-transfer models overlaid on data.

Not supported. Separate specialist codes.

Not supported. Separate specialist codes.

Results tied to samples and process history

Supported. Referenced positions, widths, and area fractions are stored as structured outputs linked to the file, parameters, sample, and process run.

Partly supported. Project files on the workstation; sample context kept separately.

Partly supported. Saved project files; sample context kept by hand.

Instrument control and acquisition

Not supported. Not an acquisition tool. Keep your instrument software for this.

Supported. Core purpose.

Not supported. Not offered.

  • Supported
  • Partly supported
  • Not supported

Reflects typical, publicly documented workflows in each category as of September 2026. Capabilities vary by product, version, and add-on module. Product names are trademarks of their respective owners.

Where Atlas stops

A result is only useful if you know its limits. These are the current boundaries, stated in the product the same way.

  • Atomic-percent quantification is not shipped yet. It needs a named sensitivity-factor set, a transmission correction, and compatible pass energies, and it is next on the roadmap. Use your current software for it today.
  • Atlas does not name a chemical state from a survey spectrum or accept a fit whose components the data cannot distinguish.
  • Area fractions are reported within a core-level region. They are not oxide thicknesses or atomic percentages.
  • The generic peak fitter refuses XPS data and points to the constrained XPS workflow instead.

Files Atlas reads

  • VAMAS (.vms, .npl)
  • PHI MultiPak (.spe, .pro depth profiles)
  • SPECS SpecsLab Prodigy (.xy)
  • Scienta Omicron (.txt)
  • CasaXPS text exports

Analysis Blocks

  • Inspect XPS spectrum
  • Identify XPS elements
  • Reference XPS energy
  • Fit XPS core level
  • Estimate XPS layer thickness
  • Look up XPS literature

Worked examples

  • Technical walkthrough · 13 min read

    From envelope to evidence: what Atlas can do with XPS

    A published MoS₂ VAMAS corpus, fresh and two years later: vendor-agnostic import, survey identification, energy referencing with recorded provenance, and a constrained Mo 3d / S 2p fit that says when it cannot tell oxide from noise — and when it can.

Questions

Is Atlas a CasaXPS alternative?
For importing, referencing, constrained fitting, and checking whether a fit is unique, yes. For atomic-percent quantification, keep CasaXPS or your vendor software for now; that capability is on the Atlas roadmap. Atlas reads CasaXPS text exports and records any CasaXPS processing embedded in a VAMAS file without silently applying it.
Can Atlas read depth profiles?
Yes. A PHI MultiPak .pro depth profile becomes one dataset per sputter cycle, with the sputter ion and energy recorded, so each cycle can be referenced and fitted like any other region.
How does Atlas handle charge referencing?
As an explicit, reviewable step. You choose a deposited marker, a Fermi edge, an internal line, or adventitious carbon, and the method, offset, and uncertainty are recorded on every derived dataset. Kinetic-energy exports are converted using the recorded source energy and work function.

Other techniques

  • Raman spectroscopy
  • Photoluminescence spectroscopy
  • X-ray diffraction
  • Atomic force microscopy

Bring your XPS data

Send us a file from your own instrument. We’ll run it through Atlas and walk you through every number and caveat it reports.

All techniques
Matter42

A world model for your materials: know what you made and decide what to make next, with the evidence attached.

Platform

  • Atlas Metrology
  • Atlas Physics AI
  • Literature

Software

  • Raman analysis
  • PL analysis
  • XPS analysis
  • XRD analysis
  • AFM analysis

Company

  • Vision
  • Team
  • Careers
  • Blog

Resources

  • Documentation
  • Python SDK
  • Security and deployment
  • FAQ

Legal

  • Privacy Policy
  • Terms and Conditions

Social

  • LinkedIn

Copyright © 2026 Matter42. All rights reserved.

Matter42
  • Vision
Sign in

Matter42 Atlas

  • Atlas Metrology
  • Atlas Physics AI

Resources

  • Security
  • FAQ
  • Documentation
  • Python SDK

Company

  • Team
  • Careers
  • Blog
Vision
Sign in
Atlas Metrology/XPS

XPS analysis, from vendor file to chemical state

Atlas covers the full XPS workflow: import from every major vendor, inspection of acquisition conditions and counting statistics, energy referencing with a recorded basis and uncertainty, tiered survey identification, constrained core-level fitting with a uniqueness test, and comparison with literature values and multiplet simulations.

See a full walkthrough
Loading figure…
Constrained Mo 3d fit of an aged MoS₂ film. The MoO₃ doublet is pinned to ±0.02 eV and a perturbation test moves its area by only 4.4 %, so the 51 % oxide area fraction is reported as determined. The same test on the fresh film reported the oxide as unsupported. Data: Píš, Bondino, Sojková, Zenodo, CC-BY-4.0.
How Atlas produced this result

What Atlas does with XPS data

Every analysis runs as a documented Block with recorded parameters, so the same result can be reproduced, reviewed, and compared across samples.

  • One workflow for every vendor

    VAMAS, PHI MultiPak, SPECS Prodigy, Scienta Omicron, and CasaXPS text exports all land on the same metadata schema, so a lab with a mixed instrument fleet runs one workflow.

  • Inspection before interpretation

    Atlas reports acquisition conditions and counting statistics first, and refuses to compute statistics the measured ordinate cannot support.

  • Energy referencing with a receipt

    Reference to Au, Ag, or Cu with ISO 15472 values, to a fitted Fermi edge, or to adventitious carbon, with the basis and uncertainty of every shift written into the dataset.

  • Constrained fits, checked for uniqueness

    Templates link spin–orbit doublets and require a reason for every component. A perturbation test then shows whether the data can actually distinguish them.

  • Tiered element identification

    Survey lines are identified in confidence tiers rather than as a flat list, and a suggested assignment is never promoted to accepted automatically.

  • Literature and multiplet models

    Compare a measured binding energy with a corpus of reported values and their referencing context, or overlay an atomic-multiplet or charge-transfer simulation on a transition-metal region.

Atlas compared with legacy XPS software

Most labs already own capable XPS software. This is where Atlas adds to it, and where your existing tools are still the better choice.

X-ray photoelectron spectroscopy: Matter42 Atlas compared with instrument vendor software and desktop analysis tools
CapabilityMatter42 AtlasCloud or private deploymentInstrument vendor softwaree.g. Avantage, MultiPak, SpecsLab ProdigyDesktop analysis toolse.g. CasaXPS, Origin
Importing data from several vendors

Supported. VAMAS plus PHI, SPECS, Scienta, and CasaXPS exports, in one schema.

Partly supported. Own formats; VAMAS export usually available.

Supported. Broad format support.

Constrained fitting with linked doublets

Supported. Template-driven, with a stated reason for every component.

Supported. Standard.

Supported. Standard and highly configurable.

Checking whether a fit is unique

Supported. Perturbation test runs by default; unsupported components flagged.

Partly supported. Fit statistics; uniqueness checks usually manual.

Partly supported. Error estimates available in some tools, run on request.

Energy referencing recorded with basis and uncertainty

Supported. Every shift stored with its method and uncertainty.

Partly supported. Calibration applied; basis often kept as a note.

Partly supported. Calibration shift stored with the file.

Counting-statistics checks before fitting

Supported. Reported for every region.

Partly supported. Left to the analyst.

Partly supported. Left to the analyst.

Atomic-percent quantification

Not supported. Not yet. On the roadmap.

Supported. With built-in sensitivity-factor libraries.

Supported. With configurable sensitivity factors.

Comparison with published binding energies

Supported. Searchable corpus with referencing context and citations.

Partly supported. Built-in reference tables.

Partly supported. Element libraries; literature by hand.

Multiplet and charge-transfer simulation

Supported. Atomic-multiplet and charge-transfer models overlaid on data.

Not supported. Separate specialist codes.

Not supported. Separate specialist codes.

Results tied to samples and process history

Supported. Referenced positions, widths, and area fractions are stored as structured outputs linked to the file, parameters, sample, and process run.

Partly supported. Project files on the workstation; sample context kept separately.

Partly supported. Saved project files; sample context kept by hand.

Instrument control and acquisition

Not supported. Not an acquisition tool. Keep your instrument software for this.

Supported. Core purpose.

Not supported. Not offered.

  • Supported
  • Partly supported
  • Not supported

Reflects typical, publicly documented workflows in each category as of September 2026. Capabilities vary by product, version, and add-on module. Product names are trademarks of their respective owners.

Where Atlas stops

A result is only useful if you know its limits. These are the current boundaries, stated in the product the same way.

  • Atomic-percent quantification is not shipped yet. It needs a named sensitivity-factor set, a transmission correction, and compatible pass energies, and it is next on the roadmap. Use your current software for it today.
  • Atlas does not name a chemical state from a survey spectrum or accept a fit whose components the data cannot distinguish.
  • Area fractions are reported within a core-level region. They are not oxide thicknesses or atomic percentages.
  • The generic peak fitter refuses XPS data and points to the constrained XPS workflow instead.

Files Atlas reads

  • VAMAS (.vms, .npl)
  • PHI MultiPak (.spe, .pro depth profiles)
  • SPECS SpecsLab Prodigy (.xy)
  • Scienta Omicron (.txt)
  • CasaXPS text exports

Analysis Blocks

  • Inspect XPS spectrum
  • Identify XPS elements
  • Reference XPS energy
  • Fit XPS core level
  • Estimate XPS layer thickness
  • Look up XPS literature

Worked examples

  • Technical walkthrough · 13 min read

    From envelope to evidence: what Atlas can do with XPS

    A published MoS₂ VAMAS corpus, fresh and two years later: vendor-agnostic import, survey identification, energy referencing with recorded provenance, and a constrained Mo 3d / S 2p fit that says when it cannot tell oxide from noise — and when it can.

Questions

Is Atlas a CasaXPS alternative?
For importing, referencing, constrained fitting, and checking whether a fit is unique, yes. For atomic-percent quantification, keep CasaXPS or your vendor software for now; that capability is on the Atlas roadmap. Atlas reads CasaXPS text exports and records any CasaXPS processing embedded in a VAMAS file without silently applying it.
Can Atlas read depth profiles?
Yes. A PHI MultiPak .pro depth profile becomes one dataset per sputter cycle, with the sputter ion and energy recorded, so each cycle can be referenced and fitted like any other region.
How does Atlas handle charge referencing?
As an explicit, reviewable step. You choose a deposited marker, a Fermi edge, an internal line, or adventitious carbon, and the method, offset, and uncertainty are recorded on every derived dataset. Kinetic-energy exports are converted using the recorded source energy and work function.

Other techniques

  • Raman spectroscopy
  • Photoluminescence spectroscopy
  • X-ray diffraction
  • Atomic force microscopy

Bring your XPS data

Send us a file from your own instrument. We’ll run it through Atlas and walk you through every number and caveat it reports.

All techniques
Matter42

A world model for your materials: know what you made and decide what to make next, with the evidence attached.

Platform

  • Atlas Metrology
  • Atlas Physics AI
  • Literature

Software

  • Raman analysis
  • PL analysis
  • XPS analysis
  • XRD analysis
  • AFM analysis

Company

  • Vision
  • Team
  • Careers
  • Blog

Resources

  • Documentation
  • Python SDK
  • Security and deployment
  • FAQ

Legal

  • Privacy Policy
  • Terms and Conditions

Social

  • LinkedIn

Copyright © 2026 Matter42. All rights reserved.